What is the Precision and Accuracy of the Test Method?
There has been a great deal of debate over this test method because of large variations in results on companion test specimens. AASHTO T277 states that the results of companion samples tested by the same operator should not vary by more than 19.5%. This is an extremely large variation in allowable results. The ASTM method shows that the results of two properly conducted tests by the same operator on concrete samples from the same batch may differ as much as 42%. On companion samples tested by different laboratories, this percentage is raised to 51%. This large variability in test results indicates the relative inaccuracy of the test method while maintaining that concrete samples which lie within this large acceptable range are essentially equal in quality.
Conclusion
It is important to remember that:
- This test method does not replicate actual conditions that concrete would experience in the field. There is no condition where concrete is exposed to a 60-volt potential.
- This test method does not measure concrete permeability. What it does measure is concrete resistivity. Resistance is calculated as volts divided by current. It has been shown that there is a fair correlation between concrete resistivity and concrete permeability.
At the present time this is the only test method that is widely accepted by the concrete industry. As more and more experience is gained with this test, as well as with other test methods, new procedures may be developed that measure concrete permeability more accurately.